Installation Preparation

5

ELECTRICAL REQUIREMENTS

Single Speedcook Installation

Product rating is 120/208 or 120/240 volt, 60 Hz,

30 amps. This product must be connected to a supply

circuit of the proper voltage and frequency and

protected by a time delay fuse or circuit breaker.

Power should be supplied from a separate, dedicated

30-ampere branch circuit. Wire size must conform to

the requirements of the National Electrical Code or the

prevailing local code.

Combined Speedcook and Wall Oven Installation

When installed in combination with a GE/Monogram

single wall oven, use separate electrical junction boxes.
Refer to single oven installation instructions for

electrical requirements of that product.
These connections must be made by a qualified

electrician. All electrical connections must meet

National Electrical Code or prevailing local codes.

Combined Speedcook and Warming Drawer

Installation

When installing the Speedcook oven over a GE or

Monogram electric warming drawer, a separate 120V,

60Hz, properly grounded receptacle must be installed.

See instructions packed with the warming drawer.

WARNING

‡ The electrical power to the oven branch circuit

must be shut off while line connections are being

made.

‡ Use copper wiring only.
‡ Electrical ground is required on this appliance.

The free end of the green wire (ground wire)

must be connected to a suitable ground.

This wire must remain grounded to the oven.

‡ If cold water pipe is interrupted by plastic,

non-metallic gaskets, union connections or other

insulating materials, DO NOT use for grounding.

‡ DO NOT ground to a gas pipe.
‡ DO NOT have a fuse in the NEUTRAL or

GROUNDING circuit. A fuse in the NEUTRAL or

GROUNDING circuit could result in an electrical

shock.

‡ Check with a qualified electrician if you are in

doubt as to whether the appliance is properly

grounded.

Failure to follow these instructions could result in

serious injury or death.

INSTALL JUNCTION BOX

The conduit is located at the top right on the back of

the oven.

Locate and install the junction box within reach of the

oven conduit.
 ‡ Through the left or right sides of the cabinet wall

and into adjacent cabinet.

 ‡ Or, through the cutout floor.
 ‡ Or, in the upper cabinet.

ADVERTENCIA

‡ El encendido eléctrico al circuito paralelo deberá estar

apagado mientras se realizan las conexiones de línea.

‡ Use conductores de cobre únicamente.
‡ Este electrodoméstico requiere que se realice una conexión

a tierra. El extremo libre del cable verde (cable a tierra) debe

estar conectado a una conexión a tierra adecuada. Este

cable debe permanecer conectado a la conexión a tierra del

horno.

‡ Si la tubería de agua fría presenta interrupciones por

plásticos, juntas, conexiones de uniones u otros materiales

aislantes, NO use la misma como conexión a tierra.

‡ NO se debe conectar a tierra en una tubería de suministro

de gas.

REQUISITOS ELÉCTRICOS (Cont)

‡ NO posee un fusible en el circuito neutro o de conexión a

tierra. Un fusible en el circuito neutro o de conexión a tierra

podría ocasionar una descarga eléctrica.

‡ Consulte a un electricista calificado o personal del servicio

si tiene dudas de que el electrodoméstico se encuentre

conectado a tierra apropiadamente.

Si no se siguen estas instrucciones, se podrán

producir lesiones graves o la muerte.