Always turn your hood on before you begin cooking to establish an air flow in the kitchen. Let the hood run for a

few minutes to clean the air after you turn the range off. This will keep the whole kitchen cleaner.

Controls

The hood is “OFF” when the glass visor is pushed

completely in.
LIGHT–The light will turn “ON” when the glass visor

is pulled out approximately 1/2 inch.

BLOWER–The blower will turn “ON” when the

drawer is pulled out approximately 1

1

ø

2

inches.

The blower speed is set using the slide control,

located to the right of the drawer.

2

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
READ AND SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INFORMATION.

READ ALL INSTRUCTIONS BEFORE USING.

SAFETY PRECAUTIONS

CAUTION –

FOR GENERAL VENTILATING

USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR

EXPLOSIVE MATERIALS AND VAPORS.

WARNING –

TO REDUCE THE RISK OF

INJURY TO PERSONS IN THE EVENT OF A RANGE TOP

GREASE FIRE, OBSERVE THE FOLLOWING*:
A. SMOTHER FLAMES with a close-fitting lid,

cookie sheet or metal tray, then turn off the burner. BE

CAREFUL TO PREVENT BURNS. If the flames do not go

out immediately, EVACUATE AND CALL

THE FIRE DEPARTMENT.

B. 1(9(53,&.83$)/$0,1*3$1³<RXPD\

be burned.

C. DO NOT USE WATER, including wet dishcloths

RUWRZHOV³DYLROHQWVWHDPH[SORVLRQZLOOUHVXOW

D. 8VHDQH[WLQJXLVKHU21/<LI
1.<RXNQRZ\RXKDYHD&ODVV$%&H[WLQJXLVKHU

and you already know how to operate it.

2. The fire is small and contained in the area

where it started.

3. The fire department is being called.
4<RXFDQILJKWWKHILUHZLWK\RXUEDFNWRDQH[LW
* Based on “Kitchen Fire Safety” published by NFPA.

WARNING –

To reduce the risk of fire,

electric shock or injury to persons, observe the following:
A. Installation work and electrical wiring must be done

by qualified person(s) in accordance with all applicable

codes and standards, including fire-rated construction.

B. Sufficient air is needed for proper combustion and

exhausting of gases through the flue (chimney) of fuel

burning equipment to prevent back drafting. Follow the

heating equipment manufacturer’s guideline and safety

standards such as those published by the National

Fire Protection Association (NFPA), and the American

Society for Heating, Refrigeration and Air Conditioning

Engineers (ASHRAE), and the local code authorities.

When applicable, install any makeup (replacement)

air system in accordance with local building code

requirements. Visit GEAppliances.com for available

makeup air solutions.

C. When cutting or drilling into wall or ceiling, do not

damage electrical wiring and other hidden utilities.

D. Ducted fans must always be vented to the outdoors.

WARNING –

TO REDUCE THE RISK

OF FIRE AND TO PROPERLY EXHAUST AIR, BE SURE TO
'8&7$,52876,'(³'21279(17(;+$867$,5,172

SPACES WITHIN WALLS OR CEILINGS OR INTO ATTICS,

CRAWL SPACES OR GARAGES.

WARNING –

TO REDUCE THE RISK OF FIRE,

USE ONLY METAL DUCTWORK.

Do not attempt to repair or replace any part of your

hood unless it is specifically recommended in this guide.

All other servicing should be referred to a qualified

technician.