Installation Preparation

6

DUCT FITTINGS

8VHWKLVFKDUWWRFRPSXWHPD[LPXP

permissible lengths for duct runs to

outdoors.

Note: 'RQRWH[FHHGPD[LPXPSHUPLV

sible

equivalent lengths!

Maximum duct length:

100 ft. for range hoods.

Flexible ducting:
,IÀH[LEOHPHWDOGXFWLQJLVXVHGDOO

the equivalent feet values in the table
VKRXOGEHGRXEOHG7KHÀH[LEOHPHWDO

duct should be straight and smooth and
H[WHQGHGDVPXFKDVSRVVLEOH

Do NOTXVHÀH[LEOHSODVWLFGXFWLQJ

Total Duct Run

Note: Any home ventilation system,

such as a ventilation hood, may
LQWHUUXSWWKHSURSHUÀRZRIFRPEXVWLRQ
DLUDQGH[KDXVWUHTXLUHGE\¿UHSODFHV

gas furnaces, gas water heaters and

other naturally vented systems. To

minimize the chance of interruption of

such naturally vented systems, follow

the heating equipment manufacturer’s

guidelines and safety standards such

as those published by NFPA and

ASHRAE. When applicable, install any
PDNHXS UHSODFHPHQW DLUV\VWHPLQ

accordance with local building code

requirements. Visit GEAppliances.com
IRUDYDLODEOHPDNHXSDLUVROXWLRQV

$FWXDOOHQJWKRIVWUDLJKWGXFWSOXVGXFW¿WWLQJHTXLYDOHQW(TXLYD

lent length of duct pieces are based on actual tests conducted
E\*((YDOXDWLRQ(QJLQHHULQJDQGUHÀHFWUHTXLUHPHQWVIRUJRRG
venting performance with any ventilation hood.

This Hood Must

Use 8" Round Duct.
It Can Transition to

3-1/4" x 12" Duct.