Installation Preparation

INSTALLATION BELOW A COUNTERTOP

*NOTE: When installing the warming drawer below a cooktop, a solid barrier
must be installed at least 1” from the lowest point of the bottom of cooktop
burner box to the top of cutout. Use any solid material such as 1/4” thick
plywood. Allow at least 1/4” air gap between the barrier and the top of the
warming drawer. See label on top of the warming drawer for approved
cooktop models.

Installation below a cabinet drawer:

The warming drawer may be installed beneath a cabinet

drawer. In this installation, a solid barrier should be installed

above the warming drawer to block access. Use any solid

material such as 1/4” thick plywood. Allow at least 1/4”

air gap between the barrier and the top of the warming

drawer. Observe the 5” min. above the floor or 1” above the

toekick minimum installation height.
NOTE: If you are installing in frameless cabinets, it may

be necessary to install 1/2” wide cleats to accept drawer

mounting screws. See drawer to find exact locations of

mounting screws.

Side to Side Installation:

Install two warming drawers in separate cutouts.

Allow 2” min. between cutouts.

Install a Solid Barrier

Below a Cooktop

See Note

1-1/2” Cabinet Top

36”

Countertop

Height

1” Min.*

9-1/4”

9”

A

7”

25”

23-1/2” Min.

1/4”

Air

Gap

Solid Barrier

Electrical Outlet 42”

Max. From Right Side

Install a Solid Barrier

and a 1/4” Air Gap

Above Warming Drawer

Electrical

Outlet 16”

Max. From

Left Side

Install 2x4 or 2x2 Anti-Tip Block

Against Rear Cabinet Wall 9”

From Floor to Bottom of Block

Electrical Outlet

Flush With Side of

Cabinet 7” Max.

• When installed, the front face of the drawer will be

nearly flush with adjacent cabinetry doors.

• Drawer overlaps will conceal cut edges on all sides of

the opening.

The rough opening for the drawer must be:
– Depth: 23-1/2” min. from inside back to front of cabinet

frame.

– Width: 25-1/2” for 27” wide models,

28-1/2” for 30” wide models.

– Height: 9-1/4”.
• 5” min. above floor or 1” above toekick. 23-1/4”

from floor to bottom of cutout is recommended for under

countertop installation.

Installation below a cooktop:

Warming drawers are approved for installation below only

certain specified cooktop models. See the label attached

to the top of the warming drawer for approved models. A

solid barrier and air gap between cooktop and warming

drawer is required. See Note above.

Dimensions

A

ZTD910

28-1/2”

ZKD910

25-1/2”

Side to Side Installation

2”