GE ZIBS240PSS User Manual

Page 2

Advertising
background image

monogram.com

113

D

o

u

b

le

-dr

a

we

r

re

fr

ig

e

ra

to

r

O

u

tdo

or

/i

n

do

or

re

fr

ig

e

ra

to

r

W

in

e r

es

er

ve

, w

in

e c

h

il

le

r

b

ev

er

a

g

e c

en

te

r

Fr

e

sh

-fo

o

d

r

e

fr

ig

e

ra

to

r

b

a

r r

e

fr

ig

e

ra

to

r

A

Minimum to Wall

110

°

110

° Door

Swing

21-5/8"

23-5/8"

B

Minimum to Wall

90

°

90

° Door

Swing

Location requirements

All Monogram refrigeration modules may be closed in on
the top and sides as long as the front is unobstructed for air
circulation and door swing.

• Do not install these products where the temperatures will

go below 55°F (13°C) or above 90°F (32°C).

• Do not install where they will be subject to direct

sunlight, heat or moisture.

• These products are not designed to be stacked one over

the other.

Electrical
A 120V, 60HZ., 15- or 20-amp power supply is required. An
individual properly grounded branch circuit or circuit breaker
is recommended. Install a properly grounded 3-prong electrical
receptacle recessed into the back wall of the installation
location. See cutout illustration.

Note: GFCI (ground fault circuit interrupter) is not recommended.

Water line
Bar refrigerators are equipped with an automatic icemaker.
The water line can enter an opening in the back wall or floor
as shown in the cutout illustration. Route GE SmartConnect

kit or 1/4" O.D. copper tubing between the cold water line and
the water connection location. The installation of an easily
accessible shut-off valve in the water line is required.

Side-by-side installation

Make the most of your kitchen space with two Monogram
refrigeration modules installed together.

• Products must operate from separate properly

grounded receptacles.

Door swing clearances

All Monogram refrigeration modules are factory set for a 110°
door swing.
When installed in a corner:
• Allow the minimum door swing clearances shown. The use of

a custom panel and custom handle influences the minimum
clearances required.

• The minimum clearance shown at 90° will allow full extension

of drawers and shelves.

3/4" custom panels for fresh-food refrigerator

and bar refrigerator with icemaker

A field-installed overlay door panel is required for model
ZIFI240 and ZIBI240 refrigerators.

• The overlay panel must be secured to a 1/4"-thick backer

panel that slides into the door trim. A 0.10"-thick spacer panel
must be placed between the overlay and backer panel.

• Custom handles of your choice must be installed onto the

assembled overlay panel.

3/4" overlay panel dimensions (in inches)

A (width)

B (height)

1/4" backer

23-3/16"

29-9/16"

0.10" spacer

22-1/2"

29-1/16"

3/4" overlay

23-5/8"

30"

Assemble overlay panels with glue and screws.

• Center spacer panel on the backer panel, left to right, and top

to bottom. Secure the panels with glue.

• Center the spacer/backer panel on the overlay panel. Secure

with glue and screws. Countersink all screws.

Custom panel hinge routing
Use a 3/4" router bit to cut a notch into the back side of the
assembled panel for hinge clearance. Cut the notch 3/4" deep,
7/8" wide and 3/8" forward of the back side.

Models

A B

ZIFS240 / ZIBS240

14"

4"

ZIFI240 / ZIBI240

16"

4-1/2"

Advance planning for fresh-food refrigerator
and bar refrigerator with icemaker

Overlay

Panel

1/4"

Backer

Panel

Door

3/4" custom panels for

fresh food and bar refrigerator

3/4" custom panels for

double drawer refrigerator

.10 Inch

Spacer

B

A

1/4" Gap

12-1/2 lbs. max.

B

12-1/2 lbs. max.

3/8

3/4

Right

side

view

of

overlay
custom

panel

Route

for hinge

clearance

Front

7/8

3/8

Top

view

of

overlay
custom

panel

Route

for hinge

clearance

Front

A

B

Spacer Panel

Backer Panel

Overlay Panel

Overlay

Panel

1/4"

Backer

Panel

Door

.10 Inch

Spacer

Spacer Panel

Backer Panel

Overlay Panel

Overlay

Panel

1/4"

Backer

Panel

Door

3/4" custom panels for

fresh food and bar refrigerator

3/4" custom panels for

double drawer refrigerator

.10 Inch

Spacer

B

A

1/4" Gap

12-1/2 lbs. max.

B

12-1/2 lbs. max.

3/8

3/4

Right

side

view

of

overlay
custom

panel

Route

for hinge

clearance

Front

7/8

3/8

Top

view

of

overlay
custom

panel

Route

for hinge

clearance

Front

A

B

Spacer Panel

Backer Panel

Overlay Panel

Overlay

Panel

1/4"

Backer

Panel

Door

.10 Inch

Spacer

Spacer Panel

Backer Panel

Overlay Panel

The serial plate is located on the inside ceiling of the fresh-food
refrigerator, and on the left wall below the ice compartment of
the bar refrigerator.

Right-hand door
swing shown.
Allow the same
clearances
for left-hand
fresh-food
models on the
opposite side.

Maximum
assembled
panel weight
is 25 pounds.

Note: Right-hand
models illustrated.
Cut notches on the
opposite side for
left-hand door swing.

Advertising
This manual is related to the following products: