Operating instructions, Applications, White – GE 15279 In-Wall Spring Wound Timer User Manual

Page 2

Advertising
background image

Nut

Wire Terminal

Mounting Screw

2½” m

in

Knob

NOTE: When using the provided wall plate, screws are not required in order to secure the wall plate. The nut will hold the wall plate in position once assembled.

8. Carefully screw on the provided nut.
9. Push timer knob onto knob extension. Be sure the pointer is lined up with “OFF” on dial plate.
10. Turn power on at the circuit breaker or fuse box.

Operating Instructions

Turn knob clockwise to desired time period.
Timer will automatically turn current off at end of period.

Applications

This timer has multiple pole configurations including SPST, SPDT (3-Way), and DPST. Please see below for an explanation.

SPST (Lighting, Fans, A/C Units, Small Appliances)

SPDT (Hallways, Multi-Levels, Large Rooms)

= Wiring Nut

SPST Wiring Example

Black

Black

Black

Light

White

White

120/277 VAC

Power

Source

Spring Wound Timer

Load 1

NO

Line 2

C

Line 1

C

Load 2

NC

= Wiring Nut

SPDT Wiring Example

Black

Black

Light

White

White

120 VAC

Power

Source

Spring Wound Timer

HOT

NO

NC

Load 1

NO

Line 2

C

Line 1

C

Load 2

NC

3 Way
Switch

* For 3-Way Applications a jumper wire must be connected from Line 1

to Line 2. This is represented by the dashed line in the above diagram.


REVERSE ACTING (Load always on except when timer is engaged)

= Wiring Nut

SPST Wiring Example

Black

Black

Black

Light

White

White

120 VAC

Power

Source

Spring Wound Timer

Load 1

NO

Line 2

C

Line 1

C

Load 2

NC

15279 Manual

10/18/10

www.jascoproducts.com/timer

Advertising