RT-94882SL FIBER CONNECTIONS

The fiber optic connection to the user’s infrastructure is made via a SC connector located at the
back of the CDWM unit next to the power input. Be sure to allow sufficient room for the required
minimum bend radius of the fiber cable used. SC patchcords are supplied for the intra-fiber
connections between the CWDM and each of the 980 series and 482 series units. The
wavelength listed for each port on the CWDM must correlate with the wavelength listed on the
980 series unit to which that port is attached. The top port of the RT-482-1470/1490 connects to
the 1470nm port on the CWDM. The bottom port of the RT-482-1470/1490 connects to the
1490nm port on the CWDM. Follow the drawing below for the proper connections of the fiber
patchcords.

RT-94882SL



RR-94882SL FIBER CONNECTIONS

The fiber optic connections on the RR-94882SL are similar to those for the RT-94882SL with
the exception of the RR-482-1470/1490 data card.
On the RR-482-1470/1490, the bottom
port connects to the 1470nm port on the CWDM. The top port of the RR-482-1470/1490
connects to the 1490nm port on the CWDM. Follow the drawing on the next page for the proper
connections of the fiber patchcords.