Express L768/L1.5 User Manual

1

Quick Startup Guide

SETTING UP THE HDSL LINE

The Express L768/L1.5 works over leased or “dry” copper provided by the lo-
cal telephone company. See

Chapter 4

on page 87 for specifications on maxi-

mum distance. If the Express L768/L1.5 is to be used in a back-to-back
configuration, the line mode must be different for each unit.

1.

Connect a VT 100 async terminal, or personal computer with a terminal
emulator running 9600 N-8-1, to the

MAINTENANCE

port.

2.

Hold down the

Control

key and press

R

; then press

Enter

to display the

top menu.

3.

Using the arrow keys and

Enter

key to navigate the menu, go to the

Con-

figuration/WAN/HDSL

menu. Enter the line mode as HTU-C or HTU-R.

Each end of an HDSL circuit must be of opposite modes.

4.

Set the rate of transfer that will be used. Both devices must be set at the
same rate.

5.

Use the left arrow key or the

Escape

key to go back up the menu tree.

When asked to save HDSL parameters, type

y

.

6.

Connect the HDSL line to the RJ-45 jack labeled

HDSL

on the rear panel.

See

Appendix D

on page 103 for connector pinouts.

7.

When the Loop LED(s) remain solid, the Express L768/L1.5 is in synchro-
nization.

8.

On the Express L768, the Link LED will illuminate to indicate that PPP has
successfully negotiated.