GB

Drainage connections

A. Connect the drain
hose, without kinking it, to
a draining duct or a wall
drain fixed at a height
between 65 and 100cm
from the floor.
B. Alternatively, place it
over the edge of a basin,
sink or tub, fastening the
hose supplied to the tap.
The free end of the hose

should not be under water.

! We advise against the use of hose extensions. In case of
absolute need, the extension must have the same diameter
as the original hose and must not exceed 150 cm in length.

Electrical connection

Before plugging the appliance into the mains socket, make
sure that:
• the socket is earthed and in compliance with the

applicable law.

• the socket is able to sustain the appliance’s maximum

power load indicated in the Technical Details table (on
the right).

• the supply voltage is included within the values indicated

in the Technical Details table (on the right).

• the socket is compatible with the machines plug. If this

is not the case, replace the socket or the plug.

! The machine should not be installed in an outdoor
environment, not even when the area is sheltered, because
it may be very dangerous to leave it exposed to rain and
thunderstorms.

! When the machine is installed, the mains socket must be
within easy reach and should be connected to a suitable
electrical supply.

! Do not use extensions or multiple sockets.

! The power supply cable should never be bent or
dangerously compressed.

! The power supply cable must only be replaced by an
authorised serviceman.

! The company denies all liability if and when these norms
are not respected.

B

A

The first wash cycle

Once the appliance has been installed and before you
use it for the first time, run a wash cycle without detergent
and no laundry, setting the 90°C programme without a
pre-wash cycle.

TECHNICAL DETAILS

Models

AVXXL149

Dimensions

width 59.5 cm
height 85 cm
depth 60 cm

Capacity

from 1 to 7 kg

Electrical
connections

voltage 220 - 240 Volts 50 Hz
absorbed power 1700 - 2100 W

Water connection

maximum pressure 1 MPa (10 bar)
minimum pressure 0.05 MPa (0.5 bar)
drum capacity 53 litres

Spin speed

up to 1400 r.p.m.

Test programmes
in compliance with
regulation IEC456

programme 4
temperature 60°C
performed with a load weighing 7 kg

This appliance conforms to the
following European Community
directives:

Voltage) and subsequent amendments
- 89/336/EEC dated 03.05.89
(Electromagnetic Compatibility) and
subsequent amendments

Tr7760gb_AVXXL149.p65

12/10/05, 16.52

3

72/23/EEC dated 19/02/72 (Low

Advertising