OPERATING INSTRUCTIONS

Be sure equipment is connected to properly grounded 120 volt power supply with 15 amp circuit.
(230 volts for export models)

OPERATION

1. Press the MOTOR switch to the “ON” position.

2. Fill the spinner head with the desired amount of sugar floss. Never fill the head past the

bottom level of the filler spout.

3. Press the HEAT switch to the “ON” position.

4. Turn the HEAT CONTROL knob to heat setting HIGH.

5. Once floss starts to flow out of the head, reduce the HEAT CONTROL to the green range as

indicated on the METER (too high of a setting will cause cutting of the floss and potentially
clog the head screen)

6. When the amount of floss that is produced starts to slow, add more sugar. DO NOT adjust

the HEAT CONTROL knob setting.

7. NOTE: The typical operating setting on the heat control is in the green range. This will vary,

however due to fluctuations in environmental.

SHUTTING DOWN

1. Press HEAT switch to the “OFF” position.

2. Wait 3-5 minutes for the spinner head to cool down.

3. Press the MOTOR switch to the “OFF” position

In Case of a Malfunction immediately shut-off the MOTOR and HEAT
switches and correct the problem.