Diagnostic microprocessor control – Alliance Laundry Systems Drying Tumbler Part No. 70400401R2 User Manual

Page 13

Advertising
background image

Operation

11

70400401

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Diagnostic Microprocessor Control

General Operation

The Diagnostic Microprocessor Control (DMP) is
designed to manage the drying and cooling cycles of
the tumbler. The controller is also programmed from
the factory with five different default programs as
described in Table 1. The operator has the flexibility to
select the time for the drying and the cool down cycles
and the drying temperature. The operator may also
select either reversing or nonreversing basket action
only if the tumbler is equipped for reversing. The
operator may also reprogram the default programs.
Refer to Programming.

Default Programs

Table 1

Features

Drying time: 0-60 minutes

Cooling time: 2-60 minutes

LED display of cycle time, set temperature, and
actual temperature

Thermistor controlled temperature

Safety tumble cycle

Buzzer for end of cycle, audible alarm

Reversing/nonreversing selection

Five user programmable programs

RPM display

when equipped with rotational

sensor only

Monitors the lint door switch operation

Monitors the thermistor for operation

The minimum drying time is 0 minutes, and the
minimum cooling time is 2 minutes. The maximum
drying or cooling time is 60 minutes. The drying
temperature may be set from 100ºF (38ºC) to
185º/195ºF (85º/91ºC). The drying time, cooling time,
or temperature may be modified during an operating
cycle.

If it is necessary to reset the drying and cooling times
for the current cycle, press STOP once to stop the
tumbler. Press STOP again to cancel the cycle.

If it is necessary to change programs during a current
cycle, press STOP once to stop the tumbler and press
STOP again to cancel the current cycle.

Programs

Dry Time (Min.)

Cool Time (Min.)

Temp. Set Point

Reversing

1 – Towels

40 5

185º/195ºF

(85º/91ºC)

No

2 – Sheets

30 5

165ºF

(74ºC)

Yes

3 – Misc-1

30 5

150ºF

(66ºC)

No

4 – Misc-2

25 5

135ºF

(57ºC)

Yes

5 – Extra Dry

5 2

150ºF

(66ºC)

No

NOTE: If an altered program is determined to be corrupted, the default program settings will be used.

Advertising