Alliance Laundry Systems Drying Tumbler Part No. 70400401R2 User Manual

Page 15

Advertising
background image

Operation

13

70400401

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

DMP OPL Features

DIP Switch Settings

The DMP has an 8 position DIP switch bank that is
accessible from the back of the control board. By
switching these DIP switches, it is possible for the
operator to customize the display and some of the
operating features of the tumbler.

DIP Switch Functions Explained

1. Tumbler Type: This DIP switch selects the type

of tumbler, i.e., OPL or Coin.

2. Temperature Units: Selects ºF or ºC for the

temperature display. Factory setting is for ºF.

3. Local/Remote Reversing: Preset at the factory;

usually for local reversing. Remote reversing for
use with Reversing Timer Board only.

4. Empty: Preset at the factory; always ON.

5. Empty: Preset at the factory; always ON.

6. Buzzer Timer: This DIP switch determines the

length of time that the end of cycle buzzer will
remain on. “OFF” indicates that the buzzer will
sound for 5 seconds when the drying cycle is
completed. “ON” indicates that the buzzer will
sound continuously until the STOP button is
pressed, or the loading door is opened.

7. Safety Tumble, Display Count, or Pay: If DIP

switch #1 is set for OPL, then DIP switch #7 in
the ON position enables the safety tumble. If DIP
switch #1 is set for Coin, then DIP switch #7 in
the display of “PAy,” to indicate that coins are
needed to run the tumbler.

8. Programming: This switch enables or disables

the programming feature and should normally be
in the OFF position.

Function

OPL

Coin

1

Tumbler Type

OFF

ON

OPL=Off; Coin=On

2

Temperature Units

OFF

OFF

ºF=Off; ºC=On

3

Local/Remote

Reversing

ON

ON

Local=On; Remote=Off

4

Empty

ON

ON

Always ON

5

Empty

ON

ON

Always ON

6

Buzzer Timer

ON

ON

5 Sec=Off; Continuous=On

7

Safety Tumble (OPL)

or Coin Count/Pay

(Coin)

ON

OFF

#1

#7

DIP SWITCH

OFF

ON

SAFETY TUMBLE

OFF

OFF

NO SAFETY TUMBLE

ON

ON

COIN COUNT

ON

OFF

PAY

8

Programming

OFF

OFF

Disable=Off; Enable=On

Table 2

Advertising