11

TROUBLESHOOTING

Problem

Overall settings





Cannot set shallow
enough.


Spoke wheels not turning
continuously.



Cause

Planter not set correctly.

Planter not set correctly.



Spoke wheels not
engaging residue.







Solution

Ensure that in operation
the planter frame is at
correct height (20-22")
and level the tool bar.


See above.



Lower wheels to ensure
rotation at all times, DO
NOT
engage solid part of
wheel in dirt.