LUBRICATION

NOTE: For clarity, closing wheel assembly
has been removed from row unit.

Oil bushings weekly with general purpose oil.











TROUBLESHOOTING


Problem

Closing wheel(s) leave severe
imprint in soil.

Closing wheel(s) NOT firming
soil around seed.

Closing wheel running on top
of seed trench.


Possible Cause

Too much closing wheel down
pressure.

Insufficient closing wheel
pressure.

Closing wheels not centered.


Solution

Reduce closing wheel
pressure.

Increase closing wheel
pressure.

Rotate eccentric bushing(s) to
center closing wheels.