Installation and Operator’s Manual

Page 18 of 63

(PVI-3600-OUTD-UK-F-W Rev.: 1.0)

3.3 Choosing

Installation

Location

The location for the installation of AURORA should be selected in accordance to
the following recommendations:

AURORA should be placed at a suitable height from ground to allow easy

reading of the front display and the status LEDs.

Leave enough room around the unit to allow easy installation and

maintenance.

Choose a location sheltered from sun radiation and able to provide some

ventilation. Avoid locations where air cannot freely circulate around the
unit, or directly exposed to the sun.

The mounting location should also allow space for the Wind Interface Box

and the Diversion load.

Minimum clearance requirements on the sides easily access the side cover

and to obtain the best performance of the unit are as per the following
figure:

Fig.5 Minimum clearance requirements

500 mm (18”)

500 mm (18”)

>100 mm
(4”)

>300 mm
(12”)