Dimensions:

Capacity

(mL)

Size

(USgph)

Scale

(mL)

A

(in)

B

(in)

C

(in)

30

.95

1

14

1.4

1/4

100

3.2

2

15

2.5

1/2

200

6.4

2

21

2.5

1/2

500

16

5

15

3.5

3/4

1,000

32

5

27

3.5

3/4

2,000

63

10

27*

5.0

1

3,000

95

10

21

7.5

1 1/2

4,000

127

10

39*

5.0

1

5,000

160

10

29

7.5

1 1/2

7,000

225

10

39

7.5

1 1/2

10,000

320

20

27

9.15

2

20,000

640

20

39

9.15

2

* 2,000mL w/ PTFE End Cap ONLY, Dim A = 26 in
* 4,000mL w/ PTFE End Cap ONLY, Dim A = 38 in

Codes for Ordering Glass Calibration Cylinders:

CCG □□□□□ □

1

2

1 = Size

2 = End Cap Material

0030 - 30 mL
0100 - 100 mL

P - PVC

0200 - 200 mL

CP - CPVC

0500 - 500 mL

PP - Polypro

1000 - 1000 mL

T - PTFE

2000 - 2000 mL

K - PVDF

4000 - 4000 mL

M - 316 SS

10000 - 10000mL

A - Alloy 20

20000 - 20000 mL

Component Drawing:

6

4

5

3

2

1

Ref #

Part # - Size - Mtrl

Description

1

PC-001-_____ - ___

End Cap

2

PC-002-_____ - V

O-Ring

2

3

PC-003-_____ - PVC

Split Ring

4

PC-004-_____ - PVC

Nut

5

PC-005-_____ - CAB

Shield

1

6

PC-006-_____ - GL

Glass
Tube

1

Shield not available on 10 & 20,000 mL sizes.

2

Viton O-Ring is standard, other by request.

When ordering parts please specify size and
material code.

Website: www.griffcovalve.com

Email: [email protected]