Wiring radian series, Gs8048a wiring and external system, Gs8048a multiple inverters (stacking) – Outback Power Systems GS4048A Quick Start Guide with GSLC User Manual

Page 4: Gs4048a wiring, Ac subpanel loads, Ac generator ac distribution panel, Battery bank, Pv array #1 pv array #2, Utility grid, Ac legend

Advertising
background image

AC Subpanel

Loads

L1

L2

NEU

GROUND

L1

L2

NEU

GROUND

AC

Source

Neutral-Ground

Bond

5

6

9

10

N

FM80 #2

L N

OUT

L N

GEN

L N

GRID

FM80 #1

CAT5 Cable

Wiring

RADIAN Series

AC Generator

AC Distribution Panel

N

Generator

Start

Negative

Positive

Ground

BATTERY

LEGEND

Battery Bank

Vented Battery Enclosure

Negative

Positive

Ground

PV

LEGEND

Neutral

HOT L1

Ground

AC LEGEND

N

L1

When stacking in parallel configuration (GS8048A or GS4048A):
AC input and output conductors can share common connections from external AC input and output
buses. These are shown above.
Do not use the OutBack bypass assembly in the GSLC.
Connect all DC, PV, AC neutral (common), and ground wires as shown in the main GS8048A diagram.
Connect all CAT5 cables using the appropriate ports in the communications manager.

Remove

On/Off Jumper

AC Output Bus

(Loads)

O

I

O

I

O

I

O

I

O

I

O

I

O

I

O

I

O

I

O

I

O

I

O

I

PV Array #2

PV Array #1

Ground

Electrode

Conductor

(Ground Rod)

AC Input Bus

(Utility Grid)

AC Input Bus

(Generator)

GS8048A wiring and

external system

N

N

GS8048A multiple inverters (stacking)

1

2

RTS

Cable

On/Off Switch or EPO

To ports as shown below

with GSLC175-PV-120/240; PV and FLEXnet DC not shown

To

batteries

RELAY

AUX

+ -

12V
AUX

Switch

INV

Remote

Battery

Temp

RELAY

AUX

+ -

12V
AUX

Switch

INV

Remote

Battery

Temp

FLEXnet DC

Twisted-pair wiring

1
2

3
4

5
6

(+) Positive

(–) Negative

Shunt A

Battery

Sense

Shunt B

Shunt C

7
8

(–) Bus Bar

(–) Bus Bar

9

(–) FM-80 #2

(–) FM-80 #1

(–) Inverter

(–) Bus Bar

Relay Connections

(not shown)

To AC, DC, and PV as below

N

L N

OUT

L N

GEN

L N

GRID

To ports as shown below

GS4048A wiring

N
E
U

L1 L2

GRID

L1 L2

GEN

N
E
U

N
E
U

L1 L2

OUT

L2

L2

L2

L1

L1

L1

7

8

With GSLC175PV1-120/240 and grid bypass

with GSLC175-PV-120/240

and grid bypass

PV Array #1

PV Array #2

HOT L2

L2

EPO

N

L2

L1

L1

L2

5

6

9

10

10

N
E
U

L1 L2

GRID

L1 L2

GEN

N
E
U

N
E
U

L1 L2

OUT

L2

L2

L2

L1

L1

L1

Utility Grid

L2

L1

900-0162-01-00 Rev A.vsd\Page 4\2014-01-24

©2014 OutBack Power Technologies. All Rights Reserved.

1

2

7

8

9

10

L2

L1

L2

L1

RTS