Hot water odor, Anode rod inspection, Draining and flushing – State SBN85 390NE A User Manual

Page 29: Caution, Property damage hazard

Advertising
background image

29

explosion hazard

Temperature-Pressure Relief Valve

must comply with ANSI Z21.22-

CSA 4.4 and ASMe code.

Properly sized temperature-

pressure relief valve must be

installed in opening provided.

Can result in overheating and

excessive tank pressure.

Can cause serious injury or death.

hot water odor

On occasion, hot water may develop a strong odor. If this occurs

drain the heater completely, flush thoroughly, and refill. If the problem

persists, chlorination of the heater and replacement of magnesium

anodes with aluminum anodes may correct the condition.
Occasionally water softener companies recommend removal of

heater anodes for odor reasons.
Unauthorized removal of the anode(s) will void the warranty. For

further information contact your dealer.

anode rod inspeCtion

Property Damage Hazard

Avoid water heater damage.

Inspection and replacement of anode rod required.

CAUTION

The anode rod is used to protect the tank from corrosion. Most

hot water tanks are equipped with an anode rod. The submerged

rod sacrifices itself to protect the tank. Instead of corroding tank,

water ions attack and eat away the anode rod. This does not

affect water’s taste or color. The rod must be maintained to keep

tank in operating condition.
Anode deterioration depends on water conductivity, not necessarily

water condition. A corroded or pitted anode rod indicates high

water conductivity and should be checked and/or replaced more

often than an anode rod that appears to be intact. replacement

of a depleted anode rod can extend the life of your water heater.

Inspection should be conducted by a qualified technician, and at

a minimum should be checked annually after the warranty period.
Artificially softened water is exceedingly corrosive because the

process substitutes sodium ions for magnesium and calcium ions.
The use of a water softener may decrease the life of the water

heater tank.
The anode rod should be inspected after a maximum of three

years and annually thereafter until the condition of the anode rod

dictates its replacement.
note: Artificially softened water requires the anode rod to be

inspected annually.

draining and flushing

Burn harzard.

Hot water discharge.

Keep hands clear of drain

valve discharge.

It is recommended that the water heater storage tank be drained

and flushed every 6 months to reduce sediment buildup. The

water heater should be drained if being shut down during freezing

temperatures. See Features And Components in this manual for

the location of the water heater components described below.
to drain the water heater storage tank:

1. Turn off the electrical supply to the water heater.

2. Turn off the gas supply at the Main Gas Shutoff Valve if the

water heater is going to be shut down for an extended period.

3. ensure the cold water inlet valve is open.

4. Open a nearby hot water faucet and let the water run until

the water is no longer hot.

5. Close the cold water inlet valve to the water heater.

6. Connect a hose to the water heater drain valve and terminate

it to an adequate drain.

7. Open the water heater drain valve and allow all the water to

drain from the storage tank.

8. Close the water heater drain valve when all water in the

storage tank has drained.

9. Close the hot water faucet opened in Step 4.

10. If the water heater is going to be shut down for an extended

period, the drain valve should be left open.

to flush the water heater storage tank:

1. Turn off the electrical supply to the water heater.

2. ensure the cold water inlet valve is open.

3. Open a nearby hot water faucet and let the water run until

the water is no longer hot. Then close the hot water faucet.

4. Connect a hose to the drain valve and terminate it to an

adequate drain.

5. ensure the drain hose is secured before and during the

entire flushing procedure. Flushing is performed with system

water pressure applied to the water heater.

6. Open the water heater drain valve to flush the storage tank.

7. Flush the water heater storage tank to remove sediment and

allow the water to flow until it runs clean.

8. Close the water heater drain valve when flushing is completed.

9. remove the drain hose.

10. Fill the water heater - see Filling The Water heater in this manual.

11. Turn on the electrical supply to place the water heater back

in operation.

12. Allow the water heater to complete several heating cycles to

ensure it is operating properly.

reCommended proCedure for periodiC

remoVal of lime deposits from tank type

CommerCial water heaters

The amount of calcium carbonate (lime) released from water is

in direct proportion to water temperature and usage, see chart.

The higher the water temperature or water usage, the more lime

deposits are dropped out of the water. This is the lime scale

which forms in pipes, heaters and on cooking utensils.