Programming – Aprilaire 8600 User Manual

Page 11

Advertising
background image

11

UNDERSTANDING pROGRAM SCHEDUlES

(CONTINUED)

pROGRAMMING

optionally, the thermostat can be set to a two event or commercial schedule. (see setup Menu on page 17.)

Event designator

Start time

Set temperature

fan

Heat

Cool

wAkE/oCCuPiED

6:00AM

70°F (21°C)

78°F (26°C)

AUTO

LEAVE/unoCCuPiED

10:00PM

62°F (17°C)

82°F (28°C)

AUTO

pROGRESSIVE RECOVERy

The Progressive recovery feature allows the thermostat to activate the heating and cooling equipment prior to an
event in order to reach the desired temperature at the start of the next scheduled event .
Example: if the wAkE time is 6 am, and the temperature is 70°, the heat will come on before 6 am, so the
temperature is 70° by the time you wake at 6 am .