INSTALLATION AND

MAINTENANCE GUIDE

Static Pressure Head

SPH20

– Eliminates effectively wind

disturbances from pressure
measurements

– Adaptable

to many barometers,

directly to Vaisala PTB210

– Fits to severe outdoor applications

INTRODUCTION

Vaisala model SPH20 Pressure Head provides an effective
elimination of pressure variations in the barometer due to the
wind. The heated plates offer an excellent outdoor performance
in cold, icy and wet conditions. The SPH20 can be integrated
directly with the Vaisala PTB210 barometer or any other
barometer.

ASSEMBLING

Screw the lower bar to the threaded sleeve of the lower plates
(with 6 holes).

MOUNTING

Select an open location, prefereably a place higher than the
surroundings, with no buildings or trees nearby. Attach the
SPH20 to a horizontal pole using a mounting plate. A suitable
pole is Vaisala sensor mast, type DKP12. However, any other
horizontal pole with two screws (M6) in a distance of 41 mm can
be used.

NOTE

The recommended distance of the SPH20
from the vertical pole is at least 1 m.


1. Loosen the two fixing screws of the pole and fix the SPH20

into the pole as indicated in Figure 1.

2. Attach the SPH20 by tightening the screws. (The pressure

Head is removed by loosening the two screws).

CONNECTION TO THE VAISALA PTB210

Visualization in Figure 2.
1. Detach the threaded nipple and the gasket (see Figure 1).
2. Place the O-ring into the barometer groove.
3. Attach the PTB210 to the SPH20 with two fixing screws.

CONNECTION TO OTHER BAROMETERS

Connect the barometer to the threaded nipple (Figure 1) by using
a flexible, airtight tube with an inner diameter of 4 mm. To
prevent condence water accumulation in the tube, make sure the
entire length of the tube goes downwards from the barometer to
SPH20.

Figure 1 SPH20 Installation

Figure 2 PTB210 Barometer Connection

QUICK CONNECTOR WIRING

input (+): terminals 1 and 2
input (-): terminals 3 and 4
Always connect both inputs!