Dependency of wizard calculations intervals, Table 5, Wizard calculations intervals – Vaisala Hydromet Data Collection Platform User Manual
Page 47: E, check

Chapter 3 ____________________________________________________________ Getting Started
VAISALA_______________________________________________________________________ 45
Dependency of Wizard Calculations
Intervals
lists the Wizard calculation intervals that are
dependent on one another.
Table 5
Wizard Calculations Intervals
Function
Inputs
Interval
Note
Air temperature
measurement
QMH101/102
10 s
1 min average used as instant
value for further processing and
reporting (TAStat1m).
Relative humidity
measurement
QMH101/102
10 s
1 min average used as instant
value for further processing and
reporting (RHStat1m).
Barometric pressure
measurement
PMT16A
10 s
1 min average used as instant
value for further processing and
reporting (PAStat1m).
Rain measurement
QMR101/102
60 s
Global radiation
measurement
QMS101/102 or CM6B
10 s
1 min average used as instant
value for further processing and
reporting (SRStat1m).
Net radiation
measurement
QMN101
10 s
1 min average used as instant
value for further processing and
reporting (NRStat1m).
Soil/Water temperature
measurement
QMT103/110
10 s
1 min average used as instant
value for further processing and
reporting (TGStat1m).
Wind measurement
QMW101/110
1 s
Dewpoint temperature
calculation
QMH101/102
60 s
Frostpoint temperature
calculation
QMH101/102
60 s
Heat index calculation
QMH101/102
60 s
QFE calculation
PMT16A
QMH101/102
Pslevel setting
60 s
Pressure sensor level [m] is set
using AWS Client Common
parameters window; see Vaisala
HydroMet™ Data Collection
Platform User’s Guide, Volume 1,
section Modifying Station Settings.
QFF calculation
PMT16A
QFE calculation
QMH101/102
Altitude setting
60 s
Station altitude [m] is set using
AWS Client Common parameters
window; see Vaisala HydroMet™
Data Collection Platform User’s
Guide, Volume 1, section Modifying
Station Settings.