Table 11, and – Vaisala WS425 User Manual

Page 45

Advertising
background image

Chapter 4 ________________________________________________________________ Operation

VAISALA _______________________________________________________________________ 45

In NMEA Extended Message, the polling can be done using the
following command:

$WIP<id>Q,*<chk><cr><lf>

where

$WIP =

Fixed

text

<id>

=

Is the data ID; A … Z

Q =

Fixed

text

* =

Fixed

text

<chk>

=

Checksum (8-bit XOR, excluding $ and *)

<cr>

=

Carriage return code, ASCII 0DH

<lf>

=

Line feed code, ASCII 0AH

Table 11

Checksum Table

ID Character
<id>

Checksum <chk> Polling String

A 72 $WIPAQ,*72<cr><lf>
B 71 $WIPBQ,*71<cr><lf>
C 70 $WIPCQ,*70<cr><lf>
D 77 $WIPDQ,*77<cr><lf>
E 76 $WIPEQ,*76<cr><lf>
F 75

$WIPFQ,*75<cr><lf>

G 74 $WIPGQ,*74<cr><lf>
H 7B

$WIPHQ,*7B<cr><lf>

I 7A

$WIPIQ,*7A<cr><lf>

J 79

$WIPJQ,*79<cr><lf>

K 78 $WIPKQ,*78<cr><lf>
L 7F

$WIPLQ,*7F<cr><lf>

M 7E $WIPMQ,*7E<cr><lf>
N 7D

$WIPNQ,*7D<cr><lf>

O 7C

$WIPOQ,*7C<cr><lf>

NOTE

When using the sensor in the NMEA Extended mode, you can either
set the output interval to zero (parameter 5 in the configuration menu)
to enable polling or use some fixed output interval.

Advertising