Wiring examples, Figure 13, Heating power connection for wind vane only – Vaisala WAC155 User Manual

Page 26: Figure

Advertising
background image

User's Guide ______________________________________________________________________

24 ___________________________________________________________________M210822EN-A

0702-021

Figure 13

Heating Power Connection for Wind Vane Only

Wiring Examples

Figure 14 on page 25

illustrates the basic wiring when the WAA151 and

WAV151 wind sensors are connected to the WAC155 transmitter.
Heating power is not connected in the figure.

Figure 15 on page 26

illustrates wiring with the WHP151 Mains Power

Supply, with heating power connected. Note that the WHP151 has
jumpers for configuring the power output. Connect pins 2-3 of the X5
jumper to set the correct voltage, and remove the X4 jumper to provide
continuous heating power. If you connect the heating in series to both
sensors as shown in the figure, set the heating power to 38 Vrms 0.5 A
by connecting pins 2-3 of the X8 jumper.

Figure 16 on page 27

illustrates the wiring with the WHP25 Mains

Power Supply and the WA252 series wind sensors. The WAC155
operating power is supplied from the WAA252 (+12Vout, F -> X2/3).
Thus no external operating voltage shall be applied to the connector X2.

NOTE

The expansion connector required for the high current wiring in

Figure

16 on page 27

is included in the WAA252 accessories

Advertising