Table 12, Inputs and outputs, Table 13 – Vaisala WAC155 User Manual

Page 58: Operating conditions, Table 14, Dimensions and mechanics, Table 12 inputs and outputs, Table 13 operating conditions, Table 14 dimensions and mechanics

Advertising
background image

User's Guide ______________________________________________________________________

56 ___________________________________________________________________M210822EN-A

Table 12

Inputs and Outputs

Property

Description/Value

Signal input:
wind direction
wind speed

6-bit parallel GRAY code
Pulse frequency 0 ... 750 Hz

Input operating power

9 ... 15.5 VDC, 8 mA typical incl. sensors
(when power-save mode is enabled)

Maximum operating power

50 mA (when power-save mode is disabled)

Input heating power

16 ... 24 VAC or VDC
32 ... 48 VAC or VDC can be used when
heating power is connected in series to both
sensors

Typical heating power

500 mA per sensor

Output signals

RS-485 serial bus

Signal cable

4 wires minimum: VIN+, VIN-, RS-485 A(-),
RS-485 B(+)

Table 13

Operating Conditions

Property

Description/Value

Temperature range:
operating
storage

-55 ... +55 °C
-60 ... +70 °C

Humidity

0 ... 100 %RH

Table 14

Dimensions and Mechanics

Property

Description/Value

Dimensions:
printed circuit board
jucntion box

115 × 58 mm

2

125 (w) × 80 (h) × 57 (d) mm

Cross arm length

800 mm

Ingress protection

IP65

Mounting

To a Ø 60 mm pole mast

Weight

1.5 kg

Material:
cross arm
junction box

AI anodized
AI painted gray

Advertising