5 configuring spare disks – HighPoint RocketRAID 2522 User Manual
Page 83

Mac OSX Driver and RAID Management Software
Adding a Spare Disk
To add a spare disk, select a disk from the Available Disks list and click Add Spare
button. This will add the disk to the Spare Pool list.
7-11
Rescan Devices
When you physically add drives to the controller while the system is running, you
can rescan the controller to reflect the change.
To rescan the devices:
Select menu “Manage - Device”.
Click “Rescan Devices” button.
Note: When you are hot-plugging an entire array, run rescan only after all array
members (hard disks) have been physically plugged or unplugged from the system.
You can rescan all the devices at once using the Rescan function on the Array
Management page.
5 Configuring Spare Disks
To configure spare disks attached to the RocketRAID card, select the “Manage -
Spare” function. The Spare Pool Management page will be displayed.