Red Lion GEMINI 33 User Manual
Page 42

APPENDIX “D” - GEMINI 3300 BATCH COUNTER MODE FUNCTION COMMAND CODE SUMMARY
-40-
CODE
MODE
DESCRIPTION
COMMENTS
62
PROCESS COUNTER RESET ACTION & PRESET TRACKING MODES
-
(+) Preset Tracking Disabled
-
(-) Preset Tracking Enabled
Preset 1 tracks Preset 2
+/-1
Manual Reset to Zero
+/-2
Manual Reset to Preset
+/-3
Auto Reset to Zero after Timed Output 2
+/-4
Auto Reset to Preset after Timed Output 2
+/-5
Auto Reset to Zero at Preset 2
+/-6
Auto Reset to Preset at Zero
63
BATCH COUNTER RESET ACTION MODES
1
Manual Reset to Zero
2
Manual Reset to Preset
3
Auto Reset to Zero after Timed Output B
4
Auto Reset to Preset after Timed Output B
5
Auto Reset to Zero at Preset B
6
Auto Reset to Preset at Zero
64
BATCH OUTPUT TERMINATION MODES
-
(+) Normal Phase
Output normally “OFF”, turns “ON” at preset.
-
(-) Reverse Phase*
Output normally “ON”, turns “OFF” at preset.
+/-3
Terminate at Manual Reset
+/-4
Terminate at Manual Reset End
+/-5
Terminate after Timed Output B
65
TIMED BATCH OUTPUT VALUE
Range 0.01 to 599.99 sec.
*Polarity sign is displayed in front of the identifier, a (-) sign is displayed, a (+) sign is not.