APPENDIX “D” - GEMINI 3300 BATCH COUNTER MODE FUNCTION COMMAND CODE SUMMARY
-41-
CODE
MODE
DESCRIPTION
COMMENTS
66
“OPERATOR ACCESSIBLE FUNCTIONS” MODES
“PGM.DIS” Terminal connected to “Comm”
-
(+) Reset Button & “RST” Terminal Enabled
Front panel reset can be independently disabled by using DIP
switch.
-
(-) Reset Button & “RST” Terminal Disabled*
Both front panel and rear terminal are disabled.
+/-1
No Functions Enabled
+/-2
Preset Programming Enabled
+/-3
Scale Factor Programming Enabled
+/-4
Preset & Scale Factor Programming Enabled
+/-5
Preset, 2-Button Reset & Counter Load Programming Enabled
+/-6
Preset, Scale Factor, 2-Button Reset & Counter Load
Programming Enabled
1
Display P
PROCESS PRESET 1
Up to +999999
1
Display B
BATCH PRESET
Up to +999999
2
Display P
PROCESS PRESET 2
Up to +999999
3
SCALE FACTOR
Up to +5.9999
E & +/- Disp P, B, T COUNTER LOAD VALUE
Up to +999999. Counter load value is saved in memory when
power is removed.
E & 1
RESET PROCESS COUNTER
E & 2
RESET BATCH COUNTER
*Polarity sign is displayed in front of the identifier, a (-) sign is displayed, a (+) sign is not.