Inputs, Outputs, Table 1 - configuration – Red Lion IAMA0006 User Manual

Page 2: Block diagram

Advertising
background image

2

16. TESTS/APPROVALS:

CC

US

US

UL

R

LISTED

PROCESS CONTROL EQUIPMENT FOR
HAZARDOUS LOCATIONS
31ZN

Class I Div 2 Groups A, B, C, D T5

A) This equipment is suitable for use in Class I, Division 2, Groups A, B,

C and D or non- hazardous locations only.

B) Warning - explosion hazard - substitution of components may impair

suitability for Class 1, Division 2.

C) Warning - explosion hazard - do not disconnect equipment unless power

has been switched off or the area is known to be non-hazardous.

17. CERTIFICATIONS AND COMPLIANCES:

1

EN 61000 corresponds to IEC 1000

2

Criterion B: Temporary impairment to operational behavior that is corrected

by the device itself.

3

Criterion A: Normal operating behavior within the defined limits.

4

EN 55011 corresponds to CISPR11

5

Class A: Area of application industry.

18. CONNECTIONS: 12 AWG max., Stripping length: 0.47" (12 mm)
19. CONSTRUCTION: Polybutylenterephthalate PBT, black
20. MOUNTING: Standard DIN top hat (T) profile rail according to EN50022

- 35x7.5

21. WEIGHT: 2 oz. (54 g)

INPUTS

The IAMA accepts a full range of process signal inputs and isolates and

converts these signals to common industrial control signals. The input signal
combinations are configured by making specific DIP switch selections on the 6
and 2 position DIP switches.

OUTPUTS

As with the input choices, the process signal output of the modules is DIP

switch selectable. The maximum output current signal is 28 mA with =500

output resistance and the maximum output voltage signal is 12.5 V with =10 K

output resistance. The transmission error without adjustment is < 0.4%. Using
the potentiometer, the error can be adjusted to < 0.1%.

TABLE 1 - CONFIGURATION

Immunity to Interference According to EN 61000-6-2

1

Discharge of static electricity (ESD)

EN 61000-4-2

Criterion B

2

Electromagnetic HF field

EN 61000-4-3

Criterion A

3

Fast transients (Burst)

EN 61000-4-4

Criterion B

2

Surge voltage capacities (Surge)

EN 61000-4-5

Criterion B

2

Conducted disturbance

EN 61000-4-6

Criterion A

3

Noise Emission According to EN 50081-2

Noise emission of housing

EN 55011

4

Class A

5

Conformance With EMC Guideline 2004/108/EC And Low Voltage Directive 2006/95/EC

I,U

1

2

IN UI

GND1

5

6

OUT UI

GND2

U

U,I

DC

DC

DC

4

3

GND3

UB +

UB +

8

7

GND3

BLOCK DIAGRAM

IN

RANGES

OUT

1

DIP SWITCHES

OUTPUT (S2)

2

3

4

5

6

1

INPUT (S1)

2

0 –10 V

0 – 20 mA

off

off

off

off

off

off

off

off

4 - 20 mA

off

off

off

off

off

ON

off

off

0 – 10 V

ON

off

ON

off

off

off

off

off

2 – 10 V

ON

off

ON

off

off

ON

off

off

0 – 5 V

ON

ON

off

off

off

off

off

off

1 – 5 V

ON

ON

off

off

off

ON

off

off

2 – 10 V

0 – 20 mA

off

off

off

ON

ON

off

off

off

4 - 20 mA

off

off

off

off

off

off

off

off

0 – 10 V

ON

off

ON

ON

ON

off

off

off

2 – 10 V

ON

off

ON

off

off

off

off

off

0 – 5 V

ON

ON

off

ON

ON

off

off

off

1 – 5 V

ON

ON

off

off

off

off

off

off

0 – 5 V

0 – 20 mA

off

off

off

off

off

off

ON

off

4 - 20 mA

off

off

off

off

off

ON

ON

off

0 – 10 V

ON

off

ON

off

off

off

ON

off

2 – 10 V

ON

off

ON

off

off

ON

ON

off

0 – 5 V

ON

ON

off

off

off

off

ON

off

1 – 5 V

ON

ON

off

off

off

ON

ON

off

1 – 5 V

0 – 20 mA

off

off

off

ON

ON

off

ON

off

4 - 20 mA

off

off

off

off

off

off

ON

off

0 – 10 V

ON

off

ON

ON

ON

off

ON

off

2 – 10 V

ON

off

ON

off

off

off

ON

off

0 – 5 V

ON

ON

off

ON

ON

off

ON

off

1 – 5 V

ON

ON

off

off

off

off

ON

off

0 – 20 mA

0 – 20 mA

off

off

off

off

off

off

off

ON

4 - 20 mA

off

off

off

off

off

ON

off

ON

0 – 10 V

ON

off

ON

off

off

off

off

ON

2 – 10 V

ON

off

ON

off

off

ON

off

ON

0 – 5 V

ON

ON

off

off

off

off

off

ON

1 – 5 V

ON

ON

off

off

off

ON

off

ON

4 - 20 mA

0 – 20 mA

off

off

off

ON

ON

off

off

ON

4 - 20 mA

off

off

off

off

off

off

off

ON

0 – 10 V

ON

off

ON

ON

ON

off

off

ON

2 – 10 V

ON

off

ON

off

off

off

off

ON

0 – 5 V

ON

ON

off

ON

ON

off

off

ON

1 – 5 V

ON

ON

off

off

off

off

off

ON

Advertising