3 bellows seal design – ARI Armaturen STEVI 460 DN 300-500 EN User Manual

Page 11

Advertising
background image

Rev. 0040304002 0410

Page 11

Operating and installation instructions

Str. thr. stop valves - STEVI

®

405 / 460 (DN300-500)

7.1.3 Bellows seal design
If the stem leaks, the bellows seal (pos. 20.3) is defective. The leak can initially be stopped
by tightening the stuffing box gland with nuts (pos. 20.29).
Stem and bellows (pos. 20.3) can only be replaced together.
Replacement of bellows seals:

- Remove actuator.

(Refer to operating instructions for actuator!)

- Loose nuts (pos. 11).
- Detach bellows assembly (pos. 20).
- Slacken nuts (pos. 20.29) by about 2-3 turns.
- Extract stem-bellows unit (pos. 20.3) from the

bellows housing (pos. 20.1).

- Drive pin (pos. 4) out with a drift.
- Unscrew stem-/bellows unit (pos. 20.3) and plug

(pos. 3).

- Bolt new parts together, drill and pin them.
- Replace 2 gaskets (pos. 20.19, 9).
- Assemble in reverse order.
- Secure with nuts (pos. 11) and tighten them

crosswise.
(For tightening torques refer to item 7.3.1)

- Tighten nuts (pos. 20.29) gradually up to tightness

of the stuffing box packing (pos. 20.10).

ATTENTION !
Refer to item 10.0 and 11.0
before dismantling the valve.

Fig. 9

Advertising