3 performance control of the membran capsule, 4 tightening torques – ARI Armaturen CONA M PN40 EN User Manual

Page 10

Advertising
background image

Page 10

Rev. 0040804000 0309

Operating and installation instructions

CONA

®

M - Thermostatic steam traps

7.3 Performance control of the membran capsule

When the diaphragm capsule is dry an cold, the diaphragm must be in contact with the top
part of the wall (as shown in Fig. 10 and Fig. 12).
If the diaphragm is away from the top surface, and/or in contact with the bottom part of the
wall (as shown in Fig. 11 and Fig. 13), the capsule is defective and should be replaced.

7.4 Tightening torques

(refert to Fig. 1 Page 4 - Fig. 9 Page 9)

Fig. 10: Capsule OPEN

Fig. 11: Capsule CLOSED

Fig. 12: Capsule (Type B) OPEN

Fig. 13: Capsule (Type B) CLOSED

Pos.

CONA M PN16

Torque (Nm)

27

Cheese head screw M10

30

3

Seat

60

Pos.

CONA M PN40

Torque (Nm)

6

Screw cap

100

3

Seat

80

8

Strainer plug

70

46

Blow down valve

70

46.1

Pressure screw

15

12

Body top (series 614)

120

12

Body top (series 619)

30

top part of wall

bottom part of wall

Membrane area

Capsule-type

top part of wall

bottom part of wall

Membrane area

Capsule-type

top part of wall

bottom part of wall

Membrane

Capsule-type

top part of wall

bottom part of wall

Membrane

Capsule-type

Advertising
This manual is related to the following products: