0 care and maintenance, 1 cleaning / replacing controller assembly – ARI Armaturen CONA M PN40 EN User Manual

Page 8

Advertising
background image

Page 8

Rev. 0040804000 0309

Operating and installation instructions

CONA

®

M - Thermostatic steam traps

7.0 Care and maintenance

Maintanance and maintenance-intervals have to be defined by the operator according to
the requirements.

7.1 Cleaning / replacing controller assembly

(refer to Fig. 1 page 4 - Fig. 8 page 5)
- Release sealing cap (Pos. 6) and cover screw connection (Pos. 28).
- Pull spring clip (Pos. 5) off radially and remove diaphragm capsule (Pos. 4) from seat

(Pos. 3).

Series 612/613:
- Unscrew strainer plug (Pos. 8), removed strainer sleeve (Pos. 7) and clean components /

seal faces.

- Fit strainer sleeve (Pos. 7), making sure that the sealing faces are clean.
- Tighten strainer plug (Pos. 8) (see 7.4).
Series 614:
- Unscrew top part of body (Pos. 12) from bottom part of body (Pos. 13).
- Remove strainer (Pos. 2)
- Pull spring clip (Pos. 5) off radially and remove diaphragm capsule (Pos. 4) from bottom of

body (Pos. 13).

Series 619:
- Unscrew top of body (Pos. 12) from bottom of body (Pos. 13).
- There are appropriate drillings in the bottom of the body (Pos. 13) to hold against. Please

use special tool.

- Remove strainer (Pos. 2).
- Take out diaphragm capsule (Pos. 4).
- Clean all components as described above.

- Assemble in reverse order (see 7.4).

Series 615:
- Because of its welded construction, this version cannot be dismantled. It can therefore

only be cleaned by reverse blowing with compressed air.

- Remove any blockage of the strainer (Pos. 2) through the inlet duct.

ATTENTION !
- refer to item 10.0 and 11.0 prio
r to dismantling and repair work!
- refer to item 6.0 befo
re restarting the plant!
Prior to installation, threads and seal faces should be coated with temperature-
stable lubricant (e.g. “OKS Anti-Seize Paste” white/metal-free).

Advertising