2 option drip pipe with union joint, 3 tightening torques, Age 8) – ARI Armaturen Air vent PN 40 EN User Manual
Page 8
Advertising

Page 2-8
Rev. 0040807004 2714
Operating and installation instructions
Automatic air vent
- Assemble in reverse order (see 7.3).
7.2 Option drip pipe with union joint
7.3 Tightening torques
(refer to Fig. 1 page 4 - Fig. 3 page 8)
Fig. 3: Controller, cpl.
It is possible to install a drip line (Pos. 53/
54) at the air inlet side to safely discharge
any leaking liquid.
Note item 7.3 when installing the option.
Fig. 4
Pos.
Automatic air vent PN16-40
Torque (Nm)
DN15-25
24
Controller
60
27
Cheese head screw M10
25
53
Union joint for drip pipe
60
45
Connector for vacuum breaker
60
Advertising