4 Alarms & Remote Control

4.1 Alarms

If alarms are required, the normally open or normally closed contacts of PIR or other detectors are
connected to the alarm connector as shown below. The default configuration is for normally open.

4.2 RS485 Remote Control

If RS485 remote control is required, the RS485 “A” and “B” signals connect as shown. Also connect TERM
to RS485 “B” to terminate.

4.3 RS232 Remote Control

If RS232 remote control is required, connect the transmit data (TXD) to the RS485 “B” pin and connect the
RS485 “A” pin to GROUND.