FIXATION AT CORNERS AND TEE CONNECTORS

Standard distance between pipe brackets is some 2 m.

MOUNTING OF PIPE LINES/GENERAL INSTRUCTIONS

- Shorten the pipes by sawing off and take off burrs.
- When bending the pipe bending radii should not be smaller than those stated in the chart

under “U-bends/hose connections” and the bending should always be completed in a bend-
ing tool with rolling matrixes in order to prevent deformation of the pipe.

- Union nut and cutting ring should be greased with oil and the cutting ring should be pre-fitted

to the pipe in the screw joint or the annealed pre-mounting socket before fitting the pipe.

- Place the pipe brackets at a maximum interval of 2 m.
- Use ∅6 hexagon-headed screw with expansion joint for wall or concrete walls when
mounting wall fittings, alternatively use a knock-type anchor for concrete walls, e.g. HILTI

type HPS 8/30.

- In systems meant for hot water, care should be taken to place the pipe brackets on a straight

line in order to prevent the lengthwise expansion of the pipe.