3.5.2 Connection and disconnection of C3K pumps

The desired configuration of the DELTABOOSTER will determine this setting.

As the system may have 2 to 6 C3K pumps connected, each module location has a specific
figure connected to it.:

The current configuration is set on the 8-poled transformer (cf. Fig. 3); below is a setting for a
configuration of 4 C3Kpumps:

1
2

4
5
6
7

3

8

ON

C3K NO.1 ON
C3K NO.2 ON
C3K NO.3 OFF
C3K NO.4 ON
C3K NO.5 ON
C3K NO.6 OFF