7.2.4 Baud rate configuration

To set the baud rate operate on DIP 2.

1 2

3 4 5

6 7

8

9

0

1 2

3 4 5

6 7

8

9

0

1 2

3 4 5

6 7

8

9

0

0A

ON

1 2

3 4

5

6 7

8

U2

U1

U3

D

IP

3

D

IP

5

D

IP

4

1

2

3

4

DIP 2

Fig. 18

Dip-switches 4, 3 and 2 are used to set the

communication rate of the device according to the

table below.

SETTING THE BAUD RATE (DIP 2)

Description

SW 1

SW 2

SW 3

SW 4

SW 5-6-7-8

Configur

ation

Baud rate

selection

–

ON ON ON –

38400 baud

–

OFF ON ON –

19200 baud

–

ON OFF ON –

9600 baud

–

OFF OFF ON –

4800 baud

–

ON ON OFF –

2400 baud

–

OFF ON OFF –

1200 baud

–

ON OFF OFF –

600 baud

–

OFF OFF OFF –

300 baud

Configurations

display

ON –

–

–

–

Display ena-

bled

OFF –

–

–

–

Display disa-

bled

Tab. 5

7.2.5 Setting of the serial

communication lines

To set the serial communication lines operate on

DIP 2.
The product is designed with two RS485 serial

communication lines which can have various settings

according to the positions of dip-switches 5 and 6 on

the DIP selector.

SERIAL COMMUNICATION LINES (DIP 2)

Description

SW 1-2-3-4

SW 5

SW 6

SW 7-8

Configur

ation (see

rela

ted chapt

ers)

Serial line

–

ON ON –

Two-way RS-485 TX/

RX line

–

OFF ON –

Line RS-485-1 reception,

line RS-485-2 repetition

–

ON OFF –

Two-way RS-422 line

–

OFF OFF –

One-way RS-485 line

Tab. 6