6.1.3 Open the box

Operation valid for pump with 5m (16ft) or

11m (36ft) delivery.

Open the cover of the water-proof box and connect

as described below.

Fig. 4

6.1.4 Connection of the board

Operation valid for pump with 5m (16ft) or

11m (36ft) delivery.

Find the position of the following on the pump

control board: fuses (01), power supply terminal

J5 (02) and pump connector J3 (03).

01

02

Fig. 5

6.1.4.1 Installing the fuse

Move the fuse into the correct fuse holder

according to the input voltage.

230V

FUS1

120V

FUS2

24V

FUS3

Fig. 6

The pump is supplied with the fuse in position FUS1

(for a 230Vac power supply).
If the power supply is different position the fuse

correctly referring to the following table.

INSTAllING THE FUSE

Voltage

Fuse holder

230Vac

Fuse in FUS1

120Vac

Fuse in FUS2

24Vac

Fuse in FUS3

Tab. 1

6.1.4.2 Connection of the power supply line

The power supply cable should also be

covered by the silicone sheath (01) supplied

for this purpose, and fastened with the

corresponding tie (02).

01

02

Neutral (N)
Phase (L)

Fig. 7

Connect the power supply terminal J5 (02) to the

electric network using a suitably sectioned cable

(minimum 1.5mm²) (Fig. 5, page 4).

Use an external switch (minimum capacity

4A, 250V) to activate the pump.