Videotec PTH900 User Manual

Page 27

Advertising
background image

Pag. 9 PTH910 / PTH911 3201

Pan & tilt connection to DTMRX1/DTRX3 receiver

WARNING: before the connection, make sure that the output voltage of the receiver corresponds to pan & tilt

voltage (Refer to the identification data of the pan & tilt motor and to DTMRX1/DTRX3 manual).

Where to operate: J1 terminal block in the lower printed circuit of the pan & tilt motor (see drawing), terminal block of
the receiver (see DTMRX1/ DTRX3 manual)
Adjustments: connect the terminal block J1 of the pan & tilt motor to that of the receiver according to the following
table

Connection to the receiver

Terminal block J1 (Pan & Tilt)

COM

Com

DOWN

Down

UP

Up

RIGH

Right

LEFT

Left

AUTO

Auto

Preset connection to DTRX3 receiver (only PTH910P / PTH911P)

The following procedure has to be carried out only for PRESET pan & tilt motors connected to DTRX3.

Where to operate : J4 terminal block in the upper printed circuit of the pan & tilt motor, preset terminal block of DTRX3
(see DTRX3 manual)
Adjustments: connect the J4 terminal block of the pan & tilt motor to the preset terminal block of DTRX3 according to
the following table:

Connection to DTRX3

Meaning

Terminal block J4 (Pan & Tilt)

Vcc

+5 Volt

Vcc

Pan

Horizontal

Pan

Tilt

Vertical

Tilt

Gnd

0 Volt

Gnd

Advertising