The electrical system to which the unit is

connected must be equipped with a bipolar

circuit breaker (Listed). The minimum

distance between the contacts must be

3mm (0.1in). The circuit breaker must be

provided with protection against the fault

current towards the ground (differential)

and the overcurrent (magnetothermal,

maximum 20A).

Make sure that the power source and

connecting cables are suitable for the

power consumption of the system.

The power supply from the mains is to be connected

into terminal J1.

7 Maintaining and cleaning

7.1 Maintaining

Maintenance must be carried out by

personnel trained to operate on electrical

circuits.

7.1.1 Fuses replacement

In case of accidental short circuit or fault to the

outputs, the protection fuse (FUS1) acts .
Should it need to be replaced, the OMEGA Brand, fuse

fitted is the follow:
Model Number: FUS2ATUL
Brand: OMEGA
Models: GT520220
Alternatively, use a T 2A L 250V type fuse.

8 Disposal of waste
materials

This symbol mark and recycle system

are applied only to EU countries and not

applied to the countries in the other area of

the world.

Your product is designed and manufactured with

high quality materials and components which can be

recycled and reused.

This symbol means that electrical and electronic

equipment, at their end-of-life, should be disposed of

separately from your household waste.
Please dispose of this equipment at your local

Community waste collection or Recycling centre.
In the European Union there are separate collection

systems for used electrical and electronic products.

9 Technical data

9.1 Electrical

IRHPS230: IN 230Vac, 50/60Hz, 30W max - OUT 24Vac,

1.2A
IRHPS120: IN 120Vac, 50/60,Hz, 30W max - OUT

24Vac, 1.2A

9.2 Environment

Operating temperature: -50°C / +60°C

9.3 Certifications

IP66/IP67 according to EN60529
EN60598
EN55022, Class B
EN50130-4

10 Technical drawings

The dimensions of the drawings are in

millimetres.

31

110

25
50

30

125

75

31

110

125

Fig. 2 IRHPS.