7.1.2 Installation of housing-fitted

illuminator (OSUPPIR kit)

Fasten the plate (01) between the bottom of the

housing (02) and the bracket (03) using the screws

supplied (04).

02

01

04

03

Fig. 6

Fasten the illuminator (complete with its bracket)

using the nut and the washer.

Fig. 7

Set the vertical and horizontal inclination (Fig. 5,

page 5).
Check the resulting illumination range on the screen.

Tighten all the screws.

7.1.3 Connections

Power supply

and control

Photocell

Switch-on

threshold

regulator

Fig. 8

7.1.4 Photocell sensitivity

The photocell is set in the factory at a predetermined

luminous level, suitable for most installations

(approximately 50Lux). In the event the intervention

threshold (illuminator activation) must be adjusted

differently, loosen the plug on the illuminator rear

and proceed adjusting.
Using a Phillips screwdriver, turn the trimmer

anticlockwise to make the illuminator switch on in

low brightness conditions or clockwise to make it

switch on in better brightness conditions.

Fig. 9

Adjust the trimmer slowly, in the preset brightness

conditions, until the warning light next to the

trimmer turns on. Once you pass the threshold (LED

on), turn slightly back in the opposite direction.

After making the adjustments make sure

that the plug is closed tight to ensure

perfect sealing.

When setting the illuminator to be switched

on automatically by the embedded dusk

switch, make sure to isolate the remote

control (telemetry) cables in the power cord

(blue and brown).