6 installing and assembling, 1 installation, 1 connections – Videotec TW Serie User Manual

Page 9: 2 configuration, 1 transmitters

Advertising
background image

EN - English - I

nstruc

tions manual

7

6.2 Configuration

g

When configuring the TWT2A and TWRB2A
models take particular care to prevent
accidental contact between the tool being
used for regulation and the live parts
(230Vac), since the device must be powered
when carrying out the adjustments.

h

The configuration procedure makes it
possible to set up the unit for optimum
performance and should only be carried
out by skilled, authorised personnel.

6.2.1 Transmitters

Fig. 01

TWT2A.

Fig. 02

TWT2.

6 Installing and assembling

h

Only specialised personnel should be
allowed to install and assemble the device.

6.1 Installation

6.1.1 Connections

h

To make the connections just follow
the arrangement given in the table
below which, for each model, shows
the connector to be used according to
the type of device to be connected.

CONNECTIONS TABLE

Model

C

amer

a

Monit

or

Twist

ed pair

Po

w

er supply

TWP

BNC

---

A B

---

TWM2

BNC

---

A B

AC / DC

TWT2

GND |
VIDEO IN

---

A B

AC / DC

TWT2A

GND |
VIDEO IN

---

A B

L N

TWRB2

---

GND |
VIDEO
OUT

A B

AC / DC

TWRR2*

---

VIDEO
OUT

A B

POWER
SUPPLY

TWRB2A

---

GND |
VIDEO
OUT

A B

L N

Tab. 01 * In the TWRR2 receiver the connectors

are on the back of the rack.