3 - command set – MagTek DynaPro Mini Programmer's99875629 User Manual
Page 48

3 - Command Set
DynaPro Mini| PIN Encryption Device | Programmer’s Reference (Commands)
Page 48
Bit
7
6
5
4
3
2
1
0
Byte 2..63
“3004” (null terminated string)
Table 3-27 - Usage Table for Report 0x1A - Maximum Application Message Size
Bit
7
6
5
4
3
2
1
0
Byte 0
0x1A
Byte 1
0x01
Byte 2 to 63
“64” (null terminated string)
Table 3-28 - Usage Table for Report 0x1A – Capability String
Bit
7
6
5
4
3
2
1
0
Byte 0
0x1A
Byte 1
0x02
Byte 2..63
“V=4,SC=0,MS2=1,PFK=1,UDE=0,CE=2" (null terminated string)
Table 3-29 - Usage Table for Report 0x1A - Manufacturer
Bit
7
6
5
4
3
2
1
0
Byte 0
0x1A
Byte 1
0x03
Byte 2..63
“MagTek, Inc.” (null terminated string)
Table 3-30 - Usage Table for Report 0x1A - Product Name
Bit
7
6
5
4
3
2
1
0
Byte 0
0x1A
Byte 1
0x04
Byte 2..63
The product name is a null-terminated string containing “DynaPro Mini”
Table 3-31 - Usage Table for Report 0x1A - Serial Number
Bit
7
6
5
4
3
2
1
0
Byte 0
0x1A
Byte 1
0x05
Byte 2..63
“12345678” (null terminated string)