Section 3. Commands, Formats, Timing


23

Switch A

Switch A, Table 3-5, is primarily used to define the communication settings. The default for
Switch A is:

11100010

9600, no parity, 8 bits, send ID at power on, transmit SS & ES

Table 3-5. Switch A

Command position 1

2

3

4

5

6

7

8

Byte Position

7 6 5

4

3

2

1

0

Description

0

0

0

Baud rate 2400 (This setting may
draw too much power from the host
so it should be avoided if possible.)

0

0

1

Baud rate 4800 (This setting may
draw too much power from the host
so it should be avoided if possible.)

0

1

0

Baud

rate

9600

0

1

1

Baud

rate

14400

1

0

0

Baud

rate

19200

1

0

1

Baud

rate

38400

1

1

0

Baud

rate

57600

1

1

1

Baud rate 115200 (If the device is
put into this setting, it will no longer
be able to receive commands
unless the characters sent to the
device are spaced apart such that
there is at least 100µs of idle time
between each character. For this
reason, this setting should be
avoided if possible.)

0

0

No

parity

0

1

Even

parity

1

0

Odd

parity

1

1

Mark (Parity = 1 all the time)

0

7

bits

data

length

1

8

bits

data

length

0

Send ID at power on: No

1

Send ID at power on: Yes

0 Transmit

SS

and

ES:

No

1 Transmit

SS

and

ES:

Yes