Timing for data and strobe, Card present at connector, Figure 2-6. data and strobe timing – MagTek MT-215 TTL SINGLE OR DUAL HEAD User Manual

Page 18

Advertising
background image

MT-215 TTL, Single or Dual Head Insertion Reader


12

TIMING FOR DATA AND STROBE

Figure 2-6 shows the timing for Data and Strobe. The timing shown is for active data (see
Figure 2-5).



























Figure 2-6. Data and Strobe Timing


Card Present at Connector

The Card Present signal is low when a recorded card is being moved across the read head. The
Card Present signal is “ANDed” with the rear sensor to ensure that Card Present will go high
when the card is fully inserted into the Reader.

NOTES

1. TIME OUT OF THE CARD PRESENT SIGNAL OCCURS WITHIN

APPROXIMATELY 150 MS FROM THE LAST STROBE TRANSITION.


2. DATA IS VALID 1.0

μS (MINIMUM) BEFORE THE NEGATIVE EDGE OF

STROBE.


3. UP TO 6 OR 7 HEAD FLUX REVERSALS ARE IGNORED FOR LOW

DENSITY CONFIGURATION AND 14 OR 15 FOR HIGH DENSITY
CONFIGURATION.

CARD PRESENT

NOTE 1

0 0 0 0 0

0

DATA

0 0

1 1 1

1 1

BIT
TIME

STROBE WIDTH
APPROXIMATELY
25-50% OF BIT TIME

NOTE 3

STROBE

NOTE 2

Advertising