RS-232 Swipe Reader, 3-Track

14

Table 2-1. Baud Rate Settings

Baud Rate

SW1

SW2

2400 OFF OFF
4800 ON OFF
9600 OFF ON

19200 ON ON

Table 2-2. Parity Settings

Parity SW3 SW4

Description

ODD OFF OFF

Parity

Enabled

MARK ON OFF

Parity

Disabled

EVEN OFF ON

Parity

Enabled

SPACE ON

ON

Parity

Disabled

Switch 5: This is an option switch that sends Start of Text (STX) and End of Text (ETX)
framing characters when set to the ON position. If framing characters are not desired, set
Switch 5 to the OFF position.

Switch 6: This is an option switch that sends one Carriage Return (CR) after the last
track when set to the ON position. If this control character is not desired, set Switch 6 to
the OFF position.

Switch 7: This is an option switch that sends the Start Sentinel (SS) and the End Sentinel
(ES) framing characters when set to the ON position. If the framing characters are not
desired, set Switch 7 to the OFF position.

Switch 8: When Switch 8 is OFF, the unit is in the unbuffered mode, and data is
automatically sent to the PC without being requested. When ON, the unit is in the
buffered mode, and data is not sent to the PC until the Reader receives an Inquiry
Command.

The switches are preset at the factory as shown in Table 2-3.

Table 2-3. Factory Settings

Switch Setting

Description

SW1 OFF

SW2 ON

Baud Rate 9600

SW3 OFF
SW4 OFF

1 Start Bit, 7 Data Bits

Odd Parity, 1 Stop Bit

SW5 ON

Send STX and ETX

SW6 ON

Send CR

SW7 ON

Send SS and ES

SW8 OFF

Unbuffered Mode