22

card data transfer rate decreases the USB bus bandwidth used by the device.
The value of this property will be sent to the host when the host requests the
device’s USB endpoint descriptor.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.


Example Set MAX PACKET SIZE property Request (Hex):

Cmd Num

Data Len

Prp ID

Prp Value

01

02

03

08

Example Set MAX PACKET SIZE property Response (Hex):

Result Code Data Len

Data

00

00

Example Get MAX PACKET SIZE property Request (Hex):

Cmd Num

Data Len

Prp ID

00

01

03


Example Get MAX PACKET SIZE property Response (Hex):

Result Code Data Len

Prp Value

00

01

08


TRACK ID ENABLE PROPERTY

Property ID:

0x04

Property Type:

Byte

Length:

1 byte

Get Property:

Yes

Set Property:

Yes

Default Value:

95 (hex)

Description:

This property is defined as follows:

id

0

T

3

T

3

T

2

T

2

T

1

T

1


Id

0 – Decodes standard ISO/ABA cards only

1 – Decodes AAMV and 7-bit cards also

T

#

00 – Track Disabled

01 – Track Enabled

10 – Track Enabled/Required (Error if blank)

This property is stored in non-volatile memory, so it will persist when the unit is
power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.