Velectrical, Vi piping, Model e20b economite – Midco E20BP User Manual

Page 4: Figure 5. wiring diagram, Connection diagram, Schematic, Legend

Advertising
background image

22

2

2

44

4

4

11

1

1

33

3

3

M

M

M

MO

O

O

OTTTTO

O

O

ORRRR RRRREEEELLLLA

A

A

AYYYY

M

M

M

MO

O

O

OTTTTO

O

O

ORRRR W

W

W

WIIIITTTTHH

H

H

IIIIN

N

N

NTTTTEEEERRRRN

N

N

NA

A

A

ALLLL

IIIIN

N

N

NTTTTEEEERRRRLLLLO

O

O

OCCC

CKKK

K

SSSSW

W

W

WIIIITTTTCCC

CHH

H

H

TTT

T

TTT

T

11

1

1

22

2

2

GG

G

GN

N

N

NDD

D

D

CCC

CO

O

O

OM

M

M

MBBBBIIIIN

N

N

NA

A

A

ATTTTIIIIO

O

O

ON

N

N

N V

V

V

VA

A

A

ALLLLV

V

V

VEEEE

YYYY

YYYY

BBB

BKKK

K

BBB

BKKK

K

BBB

BKKK

K

BBB

BLLLL((((YYYY))))

RRRR((((YYYY))))

RRRR((((YYYY))))

W

W

W

W((((BBBBKKK

K))))

MODEL E20B ECONOMITE

TTT

TRRRRA

A

A

AN

N

N

NSSSSFFFFO

O

O

ORRRRM

M

M

MEEEERRRR

N

N

N

NEEEEUUU

UTTTTRRRRA

A

A

ALLLL

11

1

1222

2000

0////111

1////666

6000

0

HH

H

HO

O

O

OTTTT

TTT

THH

H

HEEEERRRRM

M

M

MO

O

O

OSSSSTTTTA

A

A

ATTTT O

O

O

ORRRR 222

2444

4V

V

V

V O

O

O

OPPPPEEEERRRRA

A

A

ATTTTIIIIN

N

N

NGGG

G

CCC

CO

O

O

ON

N

N

NTTTTRRRRO

O

O

OLLLL.... IIIIFFFF N

N

N

NO

O

O

OTTTT UUU

USSSSEEEEDD

D

D,,,, JJJJUUU

UM

M

M

MPPPPEEEERRRR TTTT----TTTT

SSSSEEEERRRRIIIIEEEESSSS CCC

CO

O

O

ON

N

N

NN

N

N

NEEEECCC

CTTTT A

A

A

ALLLLLLLL 111

1222

2000

0V

V

V

V

O

O

O

OPPPPEEEERRRRA

A

A

ATTTTIIIIN

N

N

NGGG

G A

A

A

AN

N

N

NDD

D

D////O

O

O

ORRRR LLLLIIIIM

M

M

MIIIITTTT CCC

CO

O

O

ON

N

N

NTTTTRRRRO

O

O

OLLLLSSSS

FFFFUU

U

USSSSEEEEDD

D

D DD

D

DIIIISSSSCCC

CO

O

O

ON

N

N

NN

N

N

NEEEECCC

CTTTT

BBB

BLLLL

W

W

W

W((((BBBBKKK

K))))

TTT

THH

H

H

TTT

TRRRR

TTT

TEEEERRRRM

M

M

MIIIIN

N

N

NA

A

A

ALLLL

SSSSTTT

TRRRRIIIIPPPP

CONNECTION DIAGRAM

SSSSPPPPLLLLIIIICCC

CEEEE

BBB

BKKK

K

BBB

BKKK

K((((W

W

W

W))))

D

D

D

DA

A

A

ASSSSHH

H

HEEEEDD

D

D:::: W

W

W

WIIIIRRRRIIIIN

N

N

NGGG

G A

A

A

AN

N

N

NDD

D

D

CCC

CO

O

O

OM

M

M

MPPPPO

O

O

ON

N

N

NEEEEN

N

N

NTTTTSSSS BBBBYYYY IIIIN

N

N

NSSSSTTTTA

A

A

ALLLLLLLLEEEERRRR

22

2

2

11

1

1

N

N

N

NEEEEUUU

UTTTTRRRRA

A

A

ALLLL

M

M

M

MO

O

O

OTTTTO

O

O

ORRRR

W

W

W

W((((BBBBKKK

K))))

BBB

BKKK

K

M

M

M

M
IIII

44

4

4

22

2

2

HH

H

HO

O

O

OTTTT

11

1

1222

2000

0 V

V

V

V CCC

CO

O

O

ON

N

N

NTTTTRRRRO

O

O

OLLLLSSSS

11

1

1222

2000

0////111

1////666

6000

0

W

W

W

W((((BBBBKKK

K))))

BBB

BKKK

K

YYYY

BBB

BLLLL((((YYYY))))

TTT

T((((LLLLEEEEFFFFTTTT))))

TTT

T((((RRRRIIIIGGG

GHH

H

HTTTT))))

22

2

2444

4V

V

V

V

22

2

2444

4V

V

V

V CCC

CO

O

O

ON

N

N

NTTTTRRRRO

O

O

OLLLL

IIIIFFFF N

N

N

NO

O

O

OTTTT UUU

USSSSEEEEDD

D

D,,,, JJJJUUU

UM

M

M

MPPPPEEEERRRR TTTT----TTTT

M

M

M

M

11

1

1

33

3

3

M

M

M

MO

O

O

OTTTTO

O

O

ORRRR RRRREEEELLLLA

A

A

AYYYY

SSSSPPPPSSSSTTT

T N

N

N

N....O

O

O

O....

BBB

BLLLL

YYYY

RRRR((((YYYY))))

IIIIN

N

N

NTTTTEEEERRRRLLLLO

O

O

OCCC

CKKK

K SSSSW

W

W

WIIIITTTTCCC

CHH

H

H

RRRR((((YYYY))))

BBB

BKKK

K((((W

W

W

W))))

CCC

CO

O

O

OM

M

M

MBBBBIIIIN

N

N

NA

A

A

ATTTTIIIIO

O

O

ON

N

N

N

V

V

V

VA

A

A

ALLLLV

V

V

VEEEE

GG

G

GRRRRO

O

O

OUUU

UN

N

N

NDD

D

D

BBB

BA

A

A

ARRRR

TTT

TRRRR

TTT

THH

H

H

SCHEMATIC

SSSSO

O

O

OLLLLIIIIDD

D

D RRRRO

O

O

OUUU

UN

N

N

NDD

D

D:::: BBBBUUU

URRRRN

N

N

NEEEERRRR SSSSTTTTRRRRIIIIPPPP

O

O

O

OPPPPEEEEN

N

N

N RRRRO

O

O

OUUU

UN

N

N

NDD

D

D:::: CCC

CO

O

O

OM

M

M

MPPPPO

O

O

ON

N

N

NEEEEN

N

N

NTTTT

5

LEGEND

5

O

O

O

OPPPPTTTTIIIIO

O

O

ON

N

N

NA

A

A

ALLLL

RRRREEEED

D

D

DUUU

UN

N

N

NDD

D

DA

A

A

AN

N

N

NTTTT V

V

V

VA

A

A

ALLLLV

V

V

VEEEE

BBB

BKKK

K

SSSSPPPPLLLLIIIICCC

CEEEE

BBB

BKKK

K

SSSSO

O

O

OLLLLIIIIDD

D

D:::: W

W

W

WIIIIRRRRIIIIN

N

N

NGGG

G A

A

A

AN

N

N

NDD

D

D CCC

CO

O

O

OM

M

M

MPPPPO

O

O

ON

N

N

NEEEEN

N

N

NTTTTSSSS

BBB

BYYYY M

M

M

MIIIIDD

D

DCCC

CO

O

O

O

CAUTION: Do not add any power consuming devices in the low voltage circuit as overloading of the transformer

can result. Do not use Motor Relay to operate any external devices as overloading of motor relay contacts can result.
NOTE:
If any of the original wiring as supplied with the conversion burner must be replaced, it must be replaced with type TFF wire or
its equivalent.

Capacities shown are for a total pressure drop of 0.3"
W.C. For a higher permissible pressure drops, consult
your fuel supplier. Source, Gas Engineering Handbook -
1974

TABLE 2

Supply Pipe Capacities in MBH

20

90

145

190

225

100

60

80

125

150

225

225

TYPE

OF GAS

NATURAL

PROPANE

NATURAL

PROPANE

NATURAL

PROPANE

NATURAL

PIPE

SIZE

1/2

3/4

1

1

1/4

APPROX. CAPACITY - MBH

LENGTH OF PIPE

10

130

200

225

40

60

100

130

205

225

60

50

80

105

165

195

-4-

FIGURE 5. Wiring Diagram

V

ELECTRICAL

Installation wiring and grounding of the burner must
conform to local codes or, in their absence in the United
States to National Electric Code, ANSI/NFPA No. 70
latest edition; in Canada, to Canadian Electrical Code
Part 1, CSA Standard C22.1.

Use 14 gage copper wire, for line voltage wiring. Be

sure to hook up to a permanently live circuit. Provide a
fused on-off disconnect switch carrying a minimum 3
amp fuse.

The frame of the burner should be well grounded. A

terminal is provided on the terminal strip for positive
grounding where insulated pipe couplings are used or
where any doubt exists regarding grounding sufficiency.

Confirm that the polarity is correct -- hot wire to strip

terminal 1, neutral 2 and that the neutral line is not subject
to induced low voltage (check 2 to ground) from other
equipment .

Each installation must include suitable limit controls.

Existing oil burner combination limit and operating controls
containing cad cells.are NOT SUITABLE for gas burner
use.

Set the thermostat heat anticipator for total current draw

handled by the thermostat. The current draw of the
Economite 24V operating circuit is 0.3 amp on E20B
(NATURAL) and 0.7 amp on E20BP (PROPANE). Setting
may have to be increased on steam or gravity systems.

CAUTION: Label all wires prior to disconnection

when servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper
operation after servicing.

VI

PIPING

CAUTION: The available gas pressure should be

within the limits shown in SPECIFICATIONS section.
If the supply pressure exceeds the 14.0" W.C.
maximum, a suitable intermediate main regulator rated
for main and pilot loads must be installed ahead of the
main manual shut-off valve shown in Figure 5.

The burner gas supply piping should branch off from the

main line as close to the gas meter as possible. Do not
connect to the bottom of a horizontal section. Use new
black pipe and malleable fittings free of cutting and
threading burrs or defects.

Provide a sediment trap, union and 1/8" pressure tap in

piping close to burner as shown in Figure 5.

Use pipe joint compound resistant to Liquid Petroleum

Gases.

Piping must also comply with local codes.

To obtain the maximum firing rate of 225 MBH, the

NATURAL and PROPANE gas supply piping must be sized
to provide a minimum of 5.0" W.C. pressure to the inlet of the
combination valve when the burner and all other gas
appliances are on.

CAUTION: Because it is difficult to accurately con-

trol pressure during supply pipe leak test, it is recom-
mend that the Combination Valve be disconnected. Ex-
posing the Combination Valve to pressures over 1/2
PSIG will damage the valve and void its warranty.

DANGER: Explosion hazard. Do not use oxygen for

pressure testing. An explosion could occur during initial
start-up.

If the burner piping must be rearranged because of space

limitations, be sure to carry out the general arrangement
shown in Figure 5. Install the combination valve in any
position except up-side down.

When the burner is installed in the vestibule of equipment,

it is recommended that the combination valve be left
adjacent to the Burner within the vestibule and the Main
Manual Shut-Off Valve be installed outside.

Advertising