Part 1 Installation

Specifications

Burner Style

Power Type

Pilot Type

Intermittent, Spark Ignition (Standard)

Interrupted, Spark Ignition (Optional)

Pilot Safety

Instantaneous Electronic Flame Safeguard

Standard Voltage

C o n t r o l s

1 2 0 / 1 / 6 0

M o t o r

115/1/60 (except G69-115/230/1/60)

U.L. Listed-U.L.C. Listed

Table 1: Burner Specifications

1. Values given based on 0" W.C. firebox pressure, altitudes to 2,000 feet. Derate burner for

altitudes over 2,000 feet by 4% for each 1,000 feet over sea level.

2. Maximum inlet pressure both gases: 14" W.C. Refer to Section VI Piping for high

pressure.

3. Modulating and two-step burners are limited to a 3 to 1 turndown ratio.
4. Manifold pressures are approximate and will vary slightly according to job condition. See

Section VII Initial Start-Up paragraph 11.

5. Pressures are based on 25% excess combustion air.
6. SCFM=Standard Cubic Feet/Minute

*1 MBH=1,000 BTU/HR.

CAUTION: Unipower G-Series are not intended for outdoor installation and must be

protected from excessive moisture. Provide adequate clearance for service and proper
o p e r a t i o n .

Open basements will generally allow sufficient air infiltration, so special provisions will seldom be

required. If the heating plant is located in a separate furnace room or in an unusually tight basement,
permanent means must be provided to supply an ample volume of fresh air for combustion and boiler
room ventilation. A direct opening to the outside air should be provided sized on the basis of 1/2 square
foot of free opening for each 1,000,000 BTU of burner rating when the vent connector is equipped

I Ventilation

Natural Gas

(1,000

BTU/cu.ft.)

G56

G57

G58

G69

G56P

G57P

G58P

G69P

1075

1500

1850

2500

224

313

385

521

5.0" W.C.

7.0" W.C.

6.7" W.C.

7.5" W.C.

5.0" W.C.

5.0" W.C.

6.0" W.C.

8.0" W.C.

Propane Gas

(2,500

BTU/cu.ft.)

Natural

Propane

Maximum

Input

1

MBTU/HR.*

Maximum

Air

SCFM

6

Model

Inlet Gas Pressure

Required

2

Natural Gas

(1,000

BTU/cu.ft.)

G56

G57

G58

G69

G56P

G57P

G58P

G69P

300

300

500

800

1

/

6

1

/

3

1

/

2

3

/

4

2.2" W.C.

4.1" W.C.

4.6" W.C.

4.2" W.C.

1.2" W.C.

2.6" W.C.

3.8" W.C.

3.3" W.C.

Propane Gas

(2,500

BTU/cu.ft.)

Natural

Propane

Minimum

Input

3

MBTU/HR.*

Motor HP

(3450 RPM)

42" x 18"

48" x 21"

50" x 24"

60" x 27"

Recommended

Combustion

Chamber

Size

Model

Burner Manifold

Pressure

1,4,5

Model

G56

G57

G58

G69

300

300

500

800

1075

1500

1850

2500

950

1400

1750

2375

875

1325

1650

2275

0.7

0.8

1.0

1.0

700

1325

1400

2100

Maximum Capacity in MBH at

Combination Chamber-

Back Pressure

0" W.C.

.25" W.C. .50" W.C.

Minimum

Firing

Rate

MBH*

Maximum

Back

Pressure

in " W.C.

Maximum

MBH* at

Maximum

B.P.

Table 2: Maximum Capacity at Specified Back Pressures