Ashcroft GC52 - Rangeable wet/wet Differential Pressure Transmitter User Manual
Page 18

18
For display mode, select “Linear display mode”
==> Setting item
ባ
Set min. differential pressure P1 as “20 in.H
2
O”
==> Setting item
ቧ
Set max. differential pressure P2 as “120 in.H
2
O”
==> Setting item
ቨ
Set decimal point position of linear display
as “one digit”
==> Setting item
ቩ
Set OFFSET of linear display as “0.0m”
==> Setting item
ቪ
Set FULL SCALE of linear display as “50.0m”
==> Setting item
ቫ
Set output zero point as “0.0%F.S.”
(0.0m) of max. display span*
==> Setting item
ቭ
Set output span point as “100.0%F.S.”
(50.0m) of max. display span*
==> Setting item
ቮ
*Maximum display span: OFFSET to FULL SCALE
Ⅵ Linear display and analog output
Ex. Differential pressure 70 in.H
2
O
• Linear display: 25.0(m)
• Analog output: 12(mA)
m
(1)
8.00
Differential
Linear
Analog
Pressure
Display
Output
(in.H
2
O)
(m)
(mA)
120
==>
50.0
==> 20 Span Point
͐
͐
͐
70
==>
25.0
==> 12
20
==>
0.0
==> 4 Zero Point
(1) Put the arbitrary unit sticker.
See page 24 for full menu.