Horner APG XLt OCS HE-GSM04 User Manual
Page 46

PAGE 46
GPRS / GSM MODEM Configuration
MAN4005-04-EN
operator <stat>, long and short alphanumeric format of the name of the operator,
and numeric format representation of the operator. Any of the formats may be
unavailable and will then be an empty field (,,). The list of operators comes in the
following order: Home network, networks referenced in SIM, and other networks.
Command Functional
Group
Network Information
Command Format Query
Response
AT+COPS=?
+COPS: (2, “ “, “ “, “31022”), (3, “ “, “ “, “310380”)
OK
Write Format
Response
AT+COPS=<mode>
[, <format> [, oper>]]
OK or
+CME ERROR: <err>
Read Format
Response
AT+COPS?
+COPS: 0
OK
Execution Format
Response
N/A
N/A
Parameter Values
0
automatic (<oper> field is ignored)
1
manual (<oper> field shall be present)
2
deregister from network
3
set only <format> (for read command +COPS?), do not attempt
registration/deregistration (<oper> field is ignored); this value is not applicable
in read command response
4
manual/automatic (<oper> field shall be present); if manual selection fails,
automatic mode (<mode=0) is entered
0
long format alphanumeric <oper>
1
short format alphanumeric <oper>
<format>
2
numeric <oper>; GSM Location Area Identification Number
<oper>
operator in format as in per <format>
0
Unknown
1
Available
2
Current
<stat>
3
Forbidden
Example:
To manually register the modem on a known PLMN:
To read operator information: